FISEKON GmbH – Fischer Elektrokonstruktion

06 — Services

Schematic generation & configuration

There are plants where a hundred conveyor sections mean the same drawing a hundred times – with four changed values. Doing that by hand is not only expensive, it is the most reliable source of error in electrical design.

Where plant sections repeat, the schematic can be generated instead of drawn. The basis is verified macros and a configuration table: which drives, which sensors, which addresses, which designations. From that the complete project is produced.

The gain is not only time. A generated project is internally consistent – same structure, same naming, same terminal logic on every page. Where a hundred pages are drawn by hand, a hundred opportunities for deviation are created too.

We build the generator rules, verify the underlying macros and accompany the first runs. After that you can generate yourself – or we do it project by project.

What matters is the honest upfront check of whether the setup pays. With five variants, rarely; with fifty, almost always. We tell you that beforehand, not afterwards.

When this service is needed

  • A plant consists of many identical sections or drives.
  • Product lines differ only in a few parameters.
  • Engineering time is the bottleneck, not the design idea.
  • Deviations between identical plant sections are accumulating.

Process

How we work together

  1. 01

    Check suitability

    First we establish whether the setup pays at all. For that we look at variance: what really changes between two plant sections?

  2. 02

    Harden the macros

    A generator is only as good as the macros beneath it. These are checked, harmonised and documented before anything is generated.

  3. 03

    Build the rules

    Configuration structure, designation assignment and reports are set up and tried on a real plant section.

  4. 04

    Handover

    You receive the generator with documentation and check routine. We accompany the first projects.

Result

What you have at the end

A generator whose output nobody checks will distribute one error reliably across the entire plant. That is why the check routine is part of the delivery.

  • Verified macro library as the generator basis
  • Configuration structure and generator rules
  • Documentation of designation and address assignment
  • Check routine for generated projects

Frequently asked

From what quantity is this worthwhile?

As a rough guide: from around twenty identical units it becomes interesting, from fifty it is almost always economical. What decides is not the number alone but how stable the variance is – frequently changing requirements eat the advantage.

Do we stay dependent on you afterwards?

No. The generator runs in your environment, the rules are documented and your designers are trained. Whether you generate yourself afterwards or commission us is your decision.

Contact

Tell us what it is about.

A phone call or three lines is enough. From the very start you talk to the people who will later work on your project – not to a distribution list.

Your contact

Portrait of Olaf Kreith

Olaf Kreith

Head of Sales · Braunschweig

Head office switchboard

Locations

Head officeStellmacherstr. 7
33428 Marienfeld (Harsewinkel)
Gütersloh officeWagenfeldstr. 2
33332 Gütersloh

Or write to us

We usually reply within one working day.

Go to the contact form